FAQ


The vibrating wheel does not vibrate or vibrates weakly

Cause:
The vibratory motor is damaged or the hydraulic oil circuit is blocked
The eccentric block is worn or the connecting bolts are loose
Insufficient hydraulic fluid or oil contamination
Solution:
Inspect vibrating motors and hydraulic lines, clean blockages or replace damaged parts;
tighten the eccentric block bolts and replace the worn eccentric blocks;
Replenish or replace hydraulic oil that meets standards and filter the oil regularly.

The engine has difficulty or cannot be started

Cause:
Fuel system failures (e.g., clogged circuits, damaged fuel pumps)
Electrical system problems (low battery, faulty ignition coil)
Clogged air filters lead to insufficient air intake
Solution:
Check whether the fuel line is unblocked, replace the fuel filter;
Test the battery voltage, charge or replace if necessary;
Clean or replace the air filter to ensure smooth air intake.